{"product_id":"gwin-12-000-btu-230v-max-central-ducted-complete-system-with-15-foot-line-set-communication-wire-and-gwin-tech","title":"GWIN 12,000 BTU 230V Max Central Ducted Complete System with 15 Foot Line Set, Communication Wire, and GWIN Tech","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eGWIN 12,000 BTU 230V Max Central Ducted Complete System with 15 Foot Line Set, Communication Wire, and GWIN Tech\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGWIN 12,000 BTU 230V Max Central Ducted Complete System with 15 Foot Line Set, Communication Wire, and GWIN Tech\u003c\/strong\u003e is a Max Central Ducted R32 heat pump complete system packaged for a central ducted application. This listing keeps the indoor air-handler data and outdoor-condenser data in separate sections so each component remains clear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePairing note:\u003c\/strong\u003e This 12,000 BTU complete system uses the GMAX12HP230V1R32AH indoor air handler and the GMAX18HP230V1R32AO outdoor condenser.\u003c\/p\u003e\n\u003ch3\u003eIncluded in This Complete System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor air handler:\u003c\/strong\u003e GMAX12HP230V1R32AH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor condenser:\u003c\/strong\u003e GMAX18HP230V1R32AO\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e15 foot line set\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommunication wire\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGWIN Tech assistance for system commissioning\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGWIN Central Ducted Thermostat:\u003c\/strong\u003e G-TMAX001\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Performance\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling minimum capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling maximum capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated cooling capacity at 95°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating minimum capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating maximum capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 17°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP at 5°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling operating temperature low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling operating temperature high\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating operating temperature low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating operating temperature high\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAHRI certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e217738840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndoor Air Handler Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMAX12HP230V1R32AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMOCP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional electric heat size 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional electric heat size 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e650 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal static pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1.0 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.01 pt\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18-1\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20-5\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45-5\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e135.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndoor Air Handler Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24VAC thermostat compatible\u003c\/li\u003e\n\u003cli\u003eG-TMAX001 programmable central ducted thermostat\/controller included\u003c\/li\u003e\n\u003cli\u003eCentrifugal indoor fan\u003c\/li\u003e\n\u003cli\u003eFive fan speeds\u003c\/li\u003e\n\u003cli\u003eIndoor TXV control\u003c\/li\u003e\n\u003cli\u003eFactory-installed indoor A2L leak-detection sensor\u003c\/li\u003e\n\u003cli\u003eOptional auxiliary electric heat compatibility\u003c\/li\u003e\n\u003cli\u003eIndoor copper-tube\/aluminum-fin coil with blue anti-corrosion coil coating\u003c\/li\u003e\n\u003cli\u003eMemory \/ power-failure recovery\u003c\/li\u003e\n\u003cli\u003eSelf-diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutdoor Condenser Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMAX18HP230V1R32AO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound pressure level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMOCP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor cylinder type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor inverter stage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-stage inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29-3\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14-9\/16 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e143.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory R32 refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.4 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.108 oz\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOutdoor Condenser Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-efficiency DC inverter technology\u003c\/li\u003e\n\u003cli\u003eR32 refrigerant\u003c\/li\u003e\n\u003cli\u003eZero-lot-line outdoor-unit design\u003c\/li\u003e\n\u003cli\u003eLow-ambient cooling operation down to 5°F\u003c\/li\u003e\n\u003cli\u003eLow-ambient heating operation down to -22°F\u003c\/li\u003e\n\u003cli\u003eOutdoor electronic expansion valve (EEV)\u003c\/li\u003e\n\u003cli\u003eBasepan electric heater\u003c\/li\u003e\n\u003cli\u003eCompressor electric heater\u003c\/li\u003e\n\u003cli\u003eIntelligent defrosting\u003c\/li\u003e\n\u003cli\u003eIntelligent preheating\u003c\/li\u003e\n\u003cli\u003eOutdoor copper-tube\/aluminum-fin coil with gold anti-corrosion coil coating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRefrigerant Piping\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiquid line size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas line size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePre-charge length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum pipe elevation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFan Performance\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFan speed\u003c\/th\u003e\n\u003cth\u003e0 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.1 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.15 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.2 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.3 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.4 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.5 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.6 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.7 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.8 in. w.c.\u003c\/th\u003e\n\u003cth\u003e0.9 in. w.c.\u003c\/th\u003e\n\u003cth\u003e1.0 in. w.c.\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed 1\u003c\/td\u003e\n\u003ctd\u003e1090\u003c\/td\u003e\n\u003ctd\u003e940\u003c\/td\u003e\n\u003ctd\u003e900\u003c\/td\u003e\n\u003ctd\u003e810\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed 2\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003ctd\u003e1040\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed 3\u003c\/td\u003e\n\u003ctd\u003e1340\u003c\/td\u003e\n\u003ctd\u003e1230\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1040\u003c\/td\u003e\n\u003ctd\u003e910\u003c\/td\u003e\n\u003ctd\u003e760\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed 4\u003c\/td\u003e\n\u003ctd\u003e1680\u003c\/td\u003e\n\u003ctd\u003e1610\u003c\/td\u003e\n\u003ctd\u003e1560\u003c\/td\u003e\n\u003ctd\u003e1510\u003c\/td\u003e\n\u003ctd\u003e1430\u003c\/td\u003e\n\u003ctd\u003e1380\u003c\/td\u003e\n\u003ctd\u003e1350\u003c\/td\u003e\n\u003ctd\u003e1220\u003c\/td\u003e\n\u003ctd\u003e1130\u003c\/td\u003e\n\u003ctd\u003e970\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed 5\u003c\/td\u003e\n\u003ctd\u003e1730\u003c\/td\u003e\n\u003ctd\u003e1680\u003c\/td\u003e\n\u003ctd\u003e1630\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e1480\u003c\/td\u003e\n\u003ctd\u003e1480\u003c\/td\u003e\n\u003ctd\u003e1400\u003c\/td\u003e\n\u003ctd\u003e1310\u003c\/td\u003e\n\u003ctd\u003e1180\u003c\/td\u003e\n\u003ctd\u003e1050\u003c\/td\u003e\n\u003ctd\u003e950\u003c\/td\u003e\n\u003ctd\u003e830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eFan-performance values are CFM and are based on a dry coil with the factory filter installed. For wet-coil airflow, multiply the listed CFM by 0.96.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eIndoor Dimension Letter Reference\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension letter\u003c\/th\u003e\n\u003cth\u003eInches\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e11-5\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e16-3\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003e43-1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003ctd\u003e18-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003e21-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOutdoor Dimension Letter Reference\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension letter\u003c\/th\u003e\n\u003cth\u003eInches\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e39-3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e16-13\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e29-3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e15-9\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003e36-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003e14-9\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Electric Heat Kits\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003cth\u003eHeat-kit model\u003c\/th\u003e\n\u003cth\u003eElectric heat at 208V (kW)\u003c\/th\u003e\n\u003cth\u003eElectric heat at 230V (kW)\u003c\/th\u003e\n\u003cth\u003eMinimum circuit ampacity at 208V (A)\u003c\/th\u003e\n\u003cth\u003eMinimum circuit ampacity at 230V (A)\u003c\/th\u003e\n\u003cth\u003eMaximum fuse or breaker at 208V (A)\u003c\/th\u003e\n\u003cth\u003eMaximum fuse or breaker at 230V (A)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e320004060249\u003c\/td\u003e\n\u003ctd\u003eFLEXA2LHTR05KWD\u003c\/td\u003e\n\u003ctd\u003e3.74\u003c\/td\u003e\n\u003ctd\u003e4.6\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e29.9\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e320004060250\u003c\/td\u003e\n\u003ctd\u003eFLEXA2LHTR10KWD\u003c\/td\u003e\n\u003ctd\u003e7.49\u003c\/td\u003e\n\u003ctd\u003e9.2\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003ch4\u003eIndoor air handler\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor unit may be installed vertically or horizontally.\u003c\/li\u003e\n\u003cli\u003eHorizontal-left configuration requires no drain-pan modification.\u003c\/li\u003e\n\u003cli\u003eHorizontal-right configuration requires relocation of the drain pan.\u003c\/li\u003e\n\u003cli\u003eAllow at least 24 inches in front of the air handler for service access.\u003c\/li\u003e\n\u003cli\u003eWhen installed above a finished ceiling, place an emergency drain pan directly below the unit as required by local and state codes.\u003c\/li\u003e\n\u003cli\u003eElevate the air handler on sturdy, non-porous material where it may become wet.\u003c\/li\u003e\n\u003cli\u003eUse a protective barrier where the air handler may be exposed to physical damage.\u003c\/li\u003e\n\u003cli\u003eDesigned for a complete supply-and-return ductwork system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutdoor condenser\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the outdoor condenser at least 2 inches above the expected snow line.\u003c\/li\u003e\n\u003cli\u003eFollow the minimum clearance tables and installation manual for single-unit, side-by-side, row and stacked layouts.\u003c\/li\u003e\n\u003cli\u003eFinal refrigerant charging, electrical work and commissioning must be completed in accordance with applicable codes and the current installation manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGWIN Tech note:\u003c\/strong\u003e GWIN Tech assistance covers system commissioning only. It does not cover installation labor or incorrectly installed systems.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GWIN","offers":[{"title":"Default Title","offer_id":43010814967870,"sku":"GMAX12HP230V1R32CS","price":5774.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0624\/7622\/2526\/files\/GWIN_central_ducted_complete_bundle_1_fan.png?v=1784057593","url":"https:\/\/gwinhvac.com\/products\/gwin-12-000-btu-230v-max-central-ducted-complete-system-with-15-foot-line-set-communication-wire-and-gwin-tech","provider":"GWIN","version":"1.0","type":"link"}